| Print | E-mail
QuietRock 510
Lowest-Cost Solution for Remodels and Commercial Applications
QuietRock 510 sound damping drywall is the lowest cost, noise reduction wall panel on the market. With a simple score, snap and hang, QuietRock 510 installs and finishes like standard drywall, requiring no special tools.
QuietRock 510 Benefits
- Great value, offering solid performance at the lowest cost on the market
- Delivers STC ratings of 47-69 depending on wall assembly
- UL fire-rated (For use in fire rated assemblies)
- Ideal for remodels and upgrades – installs over existing drywall, with no demolition1
- Continues to reduce noise even when fixtures are installed, such as shelves or lamps
- Only 1/2” thick
- Outperforms other sound damping methods, including soundboard and resilient channel
- Environmentally friendly, lab tested
- Worldwide patents pending
1 Not recommended for ceiling construction.
QuietRock 510 panel for use in Design Nos. U301, U305, U309, U311, U320, U331, U334, U340, U341, U342, U440, U451, U453, U455, U465, U473, U493, V469. QuietRock 510 panel not evaluated nor intended as a substitute for the required layer(s) of UL Classified Gypsum Board in the above listed Designs.
QuietRock 510 panel for use in Design No. U347. |
• QuietRock on one side • 2x4 wood studs spaced 24” OC with 3-1/2" batt insulation • 5/8” Type X on the other
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 49 |
TL07-021 |
- |
- |
1/2” |
4-5/8” |
|
• QuietRock on both sides • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 52 |
TL07-022 |
- |
- |
1/2” |
4-1/2” |
|
• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 47 |
TL06-133 |
UL, 1 hour |
U309 |
1/2” |
5” |
|
|
• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ minimum batt insulation • 5/8” Type X on the other
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 54 |
est. |
- |
- |
1/2” |
6-5/8” |
|
• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ batt insulation • 2 layers Type X on the other
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 58 |
est. |
- |
- |
1/2” |
7-1/4” |
|
|
• QuietRock on both sides • 2x4 wood studs spaced 24” OC, 3” min. air gap with 9-1/2“ batt insulation
|
 |
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 63 |
est. |
- |
- |
1/2” |
11” |
|
• Double layer QuietRock on both sides • 2x4 wood studs spaced 24” OC, 3” min. air gap with 9-1/2“ batt insulation
|
 |
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 71 |
est. |
- |
- |
1/2” |
12” |
|
|
• One layer of QuietRock on both outer walls • 1” fire-shield shaft liner material both sides • Double 2x4 wood studs spaced 16” OC with 3-1/2” batt insulation on both sides
|
|

|
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 69 |
TL07-119 |
UL, 2 hours |
U347 |
1/2” |
11-1/2” |
|
|
• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides • 5/8” Type X on the other
|
 |
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 62 |
est. |
- |
- |
1/2” |
9” |
|
• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides
|
 |
| STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| 63 |
est. |
- |
- |
1/2” |
9” |
|
|
|