Light Gauge Double Steel Stud Walls
Find your wall assembly on the left. Use the sortable data tables on the right to select the right QuietRock solution for you.

Complete QuietRock Solutions require QuiteSeal and QuietPutty.

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides • 5/8” Type X on the other
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
62 |
est. |
- |
- |
1/2” |
9” |
| QR ES MR |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR ES |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 525 |
64 |
est. |
- |
- |
5/8” |
9-1/4” |
| QR 527 |
64 |
TL07-392 |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 528 |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 530 |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 545 |
70 |
est. |
- |
- |
1-3/8” |
10” |
|

• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
63 |
est. |
- |
- |
1/2” |
9” |
| QR ES MR |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR ES |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 525 |
65 |
est. |
- |
- |
5/8” |
9-1/4” |
| QR 527 |
65 |
TL07-391 |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 528 |
66 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 530 |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 545 |
74 |
est. |
- |
- |
1-3/8” |
10-3/4” |
|
More Assembly Types
The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.