Light Gauge Single Steel Stud Walls 24" OC

Find your wall assembly and use the data tables to select the right QuietRock solution for you.

qrgypsum400x35

quietseal120x25Complete QuietRock Solutions require QuiteSeal and QuietPutty.

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

singlesteelsmall1
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 51 est. - - 1/2” 4-5/8”
QR ES MR 55 OL11-0333 UL, 1 hour U465 5/8” 4-7/8”
QR ES 55 OL11-0333 UL, 1 hour U465 5/8” 4-7/8”
QR 525 55 TL07-028 - - 5/8” 4-7/8”
QR 527 55 TL07-069 UL, 1 hour W460, V463,
W459, V464, U465
5/8” 4-7/8”
QR 528 56 TL07-027 UL, 1 hour V463, W459 5/8” 4-7/8”
QR 530 53 est. UL, 1 hour W460, V463,
W459, V464
5/8” 4-7/8”
QR 545 62 est. - - 1-3/8” 5-5/8”

rule670x15

• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 55 est. - - 1/2” 4-5/8”
QR ES MR 57 OL11-0329 UL, 1 hour U465 5/8” 4-7/8”
QR ES 57 OL11-0329 UL, 1 hour U465 5/8” 4-7/8”
QR 525 57 TL07-029 - - 5/8” 4-7/8”
QR 527 56 TL07-076 UL, 1 hour W460, V463,
W459, V464, U465
5/8” 4-7/8”
QR 528 58 TL07-026 UL, 1 hour V463, W459 5/8” 4-7/8”
QR 530 55 TLA-05-050 UL, 1 hour W460, V463,
W459, V464
5/8” 4-7/8”
QR 545 67 est. - - 1-3/8” 6-3/8”

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other

newsingleSteel
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 54 est. - - 1/2” 5-3/8”
QR ES MR 60 OL11-0334 UL, 1 hour W460, V463, W459, V464, U465 5/8” 5-1/2”
QR ES 60 OL11-0334 UL, 1 hour W460, V463, W459, V464, U465 5/8” 5-1/2”
QR 525 60 est. - - 5/8” 5-1/2”
QR 527 60 est. UL, 1 hour W460, V463,
W459, V464, U465
5/8” 5-1/2”
QR 528 61 est. UL, 1 hour V463, W459 5/8” 5-1/2”
QR 530 58 est. UL, 1 hour W460, V463,
W459, V464
5/8” 5-1/2”
QR 545 65 est. - - 1-3/8” 6-1/4”

rule670x15

• 5/8” Type X over QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other

singlesteelsmall4
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 56 TL07-031 UL, 1 hour U465, U473 1/2” 6”
QR ES MR 62 est. UL, 1 or 2 hour W460, V463, W459, V464, U465, V419 5/8” 6-1/8”
QR ES 62 est. UL, 1 or 2 hour W460, V463, W459, V464, U465, V419 5/8” 6-1/8”
QR 525 62 est. 1 hour - 5/8” 6-1/8”
QR 527 62 est. UL, 1 or 2 hour W460, V463,
W459, V464, V419, U465
5/8” 6-1/8”
QR 528 63 est. UL, 1 hour V463, W459 5/8” 6-1/8”
QR 530 58 est. UL, 1 hour W460, V463,
W459, V464
5/8” 6-1/8”
QR 545 67 est. 1 hour - 1-3/8” 6-7/8”

More Assembly Types

singlewoodstudthumb
 
staggeredwoodthumb
 
twohoursepthumb
   
doublewoodthumb
 
singlesteelthumb
 
singlesteelthumb
   
   
doublesteelthumb
 
STC 45 to 49
 
STC 50 to 54
   
       
STC 55 to 59
 
STC 60+
 
   

The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.