QuietRock Product Selection Guide

ShareSend to FacebookTweet ThisEmail ThisPrint This

Single Wood Stud Walls

Find your wall assembly and use the data tables to select the right QuietRock solution for you.

qrgypsum400x35

quietseal120x25Complete QuietRock Solutions require QuiteSeal and QuietPutty.

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 24” OC with 3-1/2" batt insulation • 5/8” Type X on the other

singlestudwood25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 49 TL07-021 - - 1/2” 4-5/8”
QR ES MR 51 OL11-0319 UL, 1 hour U309 5/8” 4-3/4”
QR ES 51 OL11-0319 UL, 1 hour U309 5/8” 4-3/4”
QR 525 51 TL07-019 UL, 1 hour U386, W317 5/8” 4-3/4”
QR 527 50 TL10-126 UL, 1 hour U309 5/8” 4-3/4”
QR 528 50 TL07-017 UL, 1 hour U386, W317 5/8” 4-3/4”
QR 530 52 TLA-04-050 UL, 1 hour U309, U376, U386, W313, W317 5/8” 4-3/4”
QR 545 56 est. - - 1-3/8” 5-1/2”

rule670x15

• QuietRock on both sides • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

swswB25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 52 TL07-022 - - 1/2” 4-1/2”
QR ES MR 54 OL11-0320 UL, 1 hour U309 5/8” 4-3/4”
QR ES 54 OL11-0320 UL, 1 hour U309 5/8” 4-3/4”
QR 525 55 TL07-020 - - 5/8” 4-3/4”
QR 527 54 est. UL, 1 hour U309 5/8” 4-3/4”
QR 528 54 TL07-018 UL, 1½ hour U385, W318 5/8” 4-3/4”
QR 530 54 TLA-04-036 UL, 1 hour U376, W313 5/8” 4-3/4”
QR 545 60 TLA-05-048 - - 1-3/8” 6-1/4”

rule670x15

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

swswC25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 47 TL06-133 UL, 1 hour U309 1/2” 5”
QR ES MR 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR ES 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR 525 49 TLA-05-052 UL, 1 hour U386, W317 5/8” 5-3/8”
QR 527 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR 528 49 est. UL, 1 hour U386, W317 5/8” 5-3/8”
QR 530 53 TLA-04-051 UL, 1 hour U309, U376, U386, W313, W317 5/8” 5-3/8”
QR 545 58 est. 1 hour - 1-3/8” 6-1/8”

More Assembly Types

singlewoodstudthumb
 
staggeredwoodthumb
 
twohoursepthumb
   
doublewoodthumb
 
singlesteelthumb
 
singlesteelthumb
   
   
doublesteelthumb
 
STC 45 to 49
 
STC 50 to 54
   
       
STC 55 to 59
 
STC 60+
 
   

The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.

©2002-2011 Serious Energy Inc. 1250 Elko Drive Sunnyvale, CA 94089