QuietRock Product Selection Guide

ShareSend to FacebookTweet ThisEmail ThisPrint This

STC Ratings 45 - 49

qrgypsum400x35

rule670x15

Single Wood Stud Walls

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 24” OC with 3-1/2" batt insulation • 5/8” Type X on the other

singlestudwood25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 49 TL07-021 - - 1/2” 4-5/8”

rule670x15

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

swswC25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 47 TL06-133 UL, 1 hour U309 1/2” 5”
QR ES MR 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR ES 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR 525 49 TLA-05-052 UL, 1 hour U386, W317 5/8” 5-3/8”
QR 527 49 est. UL, 1 hour U309 5/8” 5-3/8”
QR 528 49 est. UL, 1 hour U386, W317 5/8” 5-3/8”

rule670x15

Heavy Gauge Single Steel Stud Walls 16" OC

rule670x15

• QuietRock on both sides • 3-5/8” 16-ga. steel studs spaced 16” OC with 3-1/2“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 44 est. - - 1/2” 4-5/8”
QR ES MR 48 TL10-394 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 4-7/8”
QR ES 48 TL10-394 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 4-7/8”
QR 525 48 est. - - 5/8” 4-7/8”
QR 527 48 est. UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 4-7/8”
QR 528 48 est. UL, 1 hour V463,W459 5/8” 4-7/8”
QR 530 48 est. UL, 1 hour V463, V464, W459, W460 5/8” 4-7/8”

rule670x15

• QuietRock on one side • 6” 16-ga. steel studs spaced 16” OC with 6“ batt insulation • 5/8” Type X on the other

singlesteelsmall1
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 45 est. - - 1/2” 7-1/8”
QR ES MR 49 TL10-398 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR ES 49 TL10-398 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR 525 49 est. - - 5/8” 7-1/4”
QR 527 49 est. UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR 528 49 est. UL, 1 hour V463,W459 5/8” 7-1/4”
QR 530 49 est. UL, 1 hour V463, V464, W459, W460 5/8” 7-1/4”

rule670x15

• QuietRock on both sides • 6” 16-ga. steel studs spaced 16” OC with 6“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 49 est. - - 1/2” 7”

More Assembly Types

singlewoodstudthumb
 
staggeredwoodthumb
 
twohoursepthumb
   
doublewoodthumb
 
singlesteelthumb
 
singlesteelthumb
   
   
doublesteelthumb
 
STC 45 to 49
 
STC 50 to 54
   
       
STC 55 to 59
 
STC 60+
 
   

The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.