QuietRock Product Selection Guide

ShareSend to FacebookTweet ThisEmail ThisPrint This

STC Ratings 50 - 54

qrgypsum400x35

rule670x15

Single Wood Stud Walls

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 24” OC with 3-1/2" batt insulation • 5/8” Type X on the other

singlestudwood25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR ES MR 51 OL11-0319 UL, 1 hour U309 5/8” 4-3/4”
QR ES 51 OL11-0319 UL, 1 hour U309 5/8” 4-3/4”
QR 525 51 TL07-019 UL, 1 hour U386, W317 5/8” 4-3/4”
QR 527 50 TL10-126 UL, 1 hour U309 5/8” 4-3/4”
QR 528 50 TL07-017 UL, 1 hour U386, W317 5/8” 4-3/4”
QR 530 52 TLA-04-050 UL, 1 hour U309, U376, U386, W313, W317 5/8” 4-3/4”

rule670x15

• QuietRock on both sides • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

swswB25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 52 TL07-022 - - 1/2” 4-1/2”
QR ES MR 54 OL11-0320 UL, 1 hour U309 5/8” 4-3/4”
QR ES 54 OL11-0320 UL, 1 hour U309 5/8” 4-3/4”
QR 527 54 est. UL, 1 hour U309 5/8” 4-3/4”
QR 528 54 TL07-018 UL, 1½ hour U385, W318 5/8” 4-3/4”
QR 530 54 TLA-04-036 UL, 1 hour U376, W313 5/8” 4-3/4”

rule670x15

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

swswC25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 530 53 TLA-04-051 UL, 1 hour U309, U376, U386, W313, W317 5/8” 5-3/8”

rule670x15

Staggered Wood Stud Walls

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ minimum batt insulation • 5/8” Type X on the other

stagwoodstudsmall1

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 54 est. - - 1/2” 6-5/8”

rule670x15

Light Gauge Single Steel Stud Walls

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

singlesteelsmall1
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 51 est. - - 1/2” 4-5/8”

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other

newsingleSteel
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 54 est. - - 1/2” 5-3/8”

rule670x15

Heavy Gauge Single Steel Stud Walls 16" OC

rule670x15

• QuietRock on both sides • 6” 16-ga. steel studs spaced 16” OC with 6“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR ES MR 53 TL10-399 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR ES 53 TL10-399 UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR 525 53 est. - - 5/8” 7-1/4”
QR 527 53 est. UL, 1 hour V463, V464, W459, W460, U425, U465 5/8” 7-1/4”
QR 528 53 est. UL, 1 hour V463,W459 5/8” 7-1/4”
QR 530 53 est. UL, 1 hour V463, V464, W459, W460 5/8” 7-1/4”

More Assembly Types

singlewoodstudthumb
 
staggeredwoodthumb
 
twohoursepthumb
   
doublewoodthumb
 
singlesteelthumb
 
singlesteelthumb
   
   
doublesteelthumb
 
STC 45 to 49
 
STC 50 to 54
   
       
STC 55 to 59
 
STC 60+
 
   

The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.