QuietRock Product Selection Guide

ShareSend to FacebookTweet ThisEmail ThisPrint This

STC Ratings 55-59

qrgypsum400x35

rule670x15

Single Wood Stud Walls

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 24” OC with 3-1/2" batt insulation • 5/8” Type X on the other

singlestudwood25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 545 56 est. - - 1-3/8” 5-1/2”

rule670x15

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

swswC25x100

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 545 58 est. 1 hour - 1-3/8” 6-1/8”

rule670x15

Staggered Wood Stud Walls

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ minimum batt insulation • 5/8” Type X on the other

stagwoodstudsmall1

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR ES MR 55 TL10-120 UL, 1 hour U340, U376, U386, W313, W317 5/8” 6-3/4”
QR ES 55 TL10-120 UL, 1 hour U340, U376, U386, W313, W317 5/8” 6-3/4”
QR 525 57 est. UL, 1 hour U386, W317 5/8” 6-3/4”
QR 527 57 TL10-123 UL, 1 hour U340, U376, U386, W313, W317 5/8” 6-3/4”
QR 528 57 est. UL, 1 hour U386, W317 5/8” 6-3/4”
QR 530 57 est. UL, 1 hour U340, U376, U386, W313, W317 5/8” 6-3/4”

rule670x15

• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ batt insulation • 2 layers Type X on the other

newStaggeredWoodWall

Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 58 est. - - 1/2” 7-1/4”
QR 525 59 est. UL, 1 hour U386W317 5/8” 7-3/8”
QR 527 59 TL10-122 UL, 1 hour U390, U376, U586, W313, W317 5/8” 7-3/8”
QR 528 59 est. UL, 1 1/2 hour U386W317 W318 5/8” 7-3/8”
QR 530 59 est. UL, 1 hour U340, U376, W313 5/8” 7-3/8”

rule670x15

Light Gauge Single Steel Stud Walls

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other

singlesteelsmall1
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR ES MR 55 OL11-0333 UL, 1 hour U465 5/8” 4-7/8”
QR ES 55 OL11-0333 UL, 1 hour U465 5/8” 4-7/8”
QR 525 55 TL07-028 - - 5/8” 4-7/8”
QR 527 55 TL07-069 UL, 1 hour W460, V463,
W459, V464, U465
5/8” 4-7/8”
QR 528 56 TL07-027 UL, 1 hour V463, W459 5/8” 4-7/8”

rule670x15

• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 55 est. - - 1/2” 4-5/8”
QR ES MR 57 OL11-0329 UL, 1 hour U465 5/8” 4-7/8”
QR ES 57 OL11-0329 UL, 1 hour U465 5/8” 4-7/8”
QR 525 57 TL07-029 - - 5/8” 4-7/8”
QR 527 56 TL07-076 UL, 1 hour W460, V463,
W459, V464, U465
5/8” 4-7/8”
QR 528 58 TL07-026 UL, 1 hour V463, W459 5/8” 4-7/8”
QR 530 55 TLA-05-050 UL, 1 hour W460, V463,
W459, V464
5/8” 4-7/8”

rule670x15

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other

newsingleSteel
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 530 58 est. UL, 1 hour W460, V463,
W459, V464
5/8” 5-1/2”

rule670x15

• 5/8” Type X over QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other

singlesteelsmall4
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 510 56 TL07-031 UL, 1 hour U465, U473 1/2” 6”
QR 530 58 est. UL, 1 hour W460, V463,
W459, V464
5/8” 6-1/8”

rule670x15

Heavy Gauge Single Steel Stud Walls 16" OC

rule670x15

• QuietRock on both sides • 3-5/8” 16-ga. steel studs spaced 16” OC with 3-1/2“ batt insulation

singlesteelsmall2
Product STC STC
Report #
Fire UL/ULC
Design #
Panel
Thickness
Assembly
Thickness
QR 545 55 est. - - 1-3/8” 5-5/8”

More Assembly Types

singlewoodstudthumb
 
staggeredwoodthumb
 
twohoursepthumb
   
doublewoodthumb
 
singlesteelthumb
 
singlesteelthumb
   
   
doublesteelthumb
 
STC 45 to 49
 
STC 50 to 54
   
       
STC 55 to 59
 
STC 60+
 
   

The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.

©2002-2011 Serious Energy Inc. 1250 Elko Drive Sunnyvale, CA 94089