STC Ratings 60 or Higher


Single Wood Stud Walls

• QuietRock on both sides • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation
|
|

|
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 545 |
60 |
TLA-05-048 |
- |
- |
1-3/8” |
6-1/4” |
|

Staggered Wood Stud Walls

• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ minimum batt insulation • 5/8” Type X on the other
|
|

|
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 545 |
64 |
est. |
- |
- |
1-3/8” |
7-1/2” |
|

• QuietRock on one side • 2x4 wood studs spaced 8” OC on 6” plates with 6“ batt insulation • 2 layers Type X on the other
|
|

|
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR ES MR |
60 |
TL10-121 |
UL, 1 hour |
U390, U376, U586, W313, W317 |
5/8” |
7-3/8” |
| QR ES |
60 |
TL10-121 |
UL, 1 hour |
U390, U376, U586, W313, W317 |
5/8” |
7-3/8” |
| QR 545 |
67 |
est. |
- |
- |
1-3/8” |
8-1/8” |
|

Two Hour Separation Wall

• One layer of QuietRock on both outer walls • 1” fire-shield shaft liner material both sides • Double 2x4 wood studs spaced 16” OC with 3-1/2” batt insulation on both sides
|
|

|
|

Double Wood Stud Walls

• QuietRock on both sides • 2x4 wood studs spaced 24” OC, 3” min. air gap with 9-1/2“ batt insulation
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
63 |
est. |
- |
- |
1/2” |
11” |
| QR ES MR |
65 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
11-1/4” |
| QR ES |
65 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
11-1/4” |
| QR 525 |
65 |
TLA-05-059 |
- |
- |
5/8” |
11-1/4” |
| QR 527 |
65 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
11-1/4” |
| QR 528 |
65 |
est. |
UL, 1½ hour |
U385, W318 |
5/8” |
11-1/4” |
| QR 530 |
66 |
TLA-04-033 |
UL, 1 hour |
U341, U376, W313 |
5/8” |
11-1/4” |
| QR 545 |
75 |
TLA-05-040 |
- |
- |
1-3/8” |
12-3/4” |
|

• Double layer QuietRock on both sides • 2x4 wood studs spaced 24” OC, 3” min. air gap with 9-1/2“ batt insulation
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
71 |
est. |
- |
- |
1/2” |
12” |
| QR ES |
73 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
12-1/2” |
| QR ES |
73 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
12-1/2” |
| QR 525 |
73 |
est. |
- |
- |
5/8” |
12-1/2” |
| QR 527 |
73 |
est. |
UL, 1 hour |
U341, U376, W313 |
5/8” |
2-1/2” |
| QR 528 |
73 |
est. |
UL, 1½ hour |
U385, W318 |
5/8” |
12-1/2” |
| QR 530 |
74 |
TLA-04-034 |
UL, 1 hour |
U341, U376, W313 |
5/8” |
12-1/2” |
| QR 545 |
80 |
TLA-05-043 |
- |
- |
1-3/8” |
15-1/2” |
|

Light Gauge Single Steel Stud Walls

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 5/8” Type X on the other
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 545 |
62 |
est. |
- |
- |
1-3/8” |
5-5/8” |
|

• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 545 |
67 |
est. |
- |
- |
1-3/8” |
6-3/8” |
|

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR ES MR |
60 |
OL11-0334 |
UL, 1 hour |
W460, V463, W459, V464, U465 |
5/8” |
5-1/2” |
| QR ES |
60 |
OL11-0334 |
UL, 1 hour |
W460, V463, W459, V464, U465 |
5/8” |
5-1/2” |
| QR 525 |
60 |
est. |
- |
- |
5/8” |
5-1/2” |
| QR 527 |
60 |
est. |
UL, 1 hour |
W460, V463, W459, V464, U465 |
5/8” |
5-1/2” |
| QR 528 |
61 |
est. |
UL, 1 hour |
V463, W459 |
5/8” |
5-1/2” |
| QR 545 |
65 |
est. |
- |
- |
1-3/8” |
6-1/4” |
|

• 5/8” Type X over QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation • 2 layers 5/8” Type X on the other
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR ES MR |
62 |
est. |
UL, 1 or 2 hour |
W460, V463, W459, V464, U465, V419 |
5/8” |
6-1/8” |
| QR ES |
62 |
est. |
UL, 1 or 2 hour |
W460, V463, W459, V464, U465, V419 |
5/8” |
6-1/8” |
| QR 525 |
62 |
est. |
1 hour |
- |
5/8” |
6-1/8” |
| QR 527 |
62 |
est. |
UL, 1 or 2 hour |
W460, V463, W459, V464, V419, U465 |
5/8” |
6-1/8” |
| QR 528 |
63 |
est. |
UL, 1 hour |
V463, W459 |
5/8” |
6-1/8” |
| QR 545 |
67 |
est. |
1 hour |
- |
1-3/8” |
6-7/8” |
|

Heavy Gauge Single Steel Stud Walls 16" OC

• QuietRock on both sides • 6” 16-ga. steel studs spaced 16” OC with 6“ batt insulation
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 545 |
60 |
est. |
- |
- |
1-3/8” |
8-3/4” |
|

Double Steel Stud Walls

• QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides • 5/8” Type X on the other
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
62 |
est. |
- |
- |
1/2” |
9” |
| QR ES MR |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR ES |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 525 |
64 |
est. |
- |
- |
5/8” |
9-1/4” |
| QR 527 |
64 |
TL07-392 |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 528 |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 530 |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 545 |
70 |
est. |
- |
- |
1-3/8” |
10” |
|

• QuietRock on both sides • 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation both sides
|
 |
| Product | STC | STC Report # | Fire | UL/ULC Design # | Panel Thickness | Assembly Thickness |
| QR 510 |
63 |
est. |
- |
- |
1/2” |
9” |
| QR ES MR |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR ES |
65 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 525 |
65 |
est. |
- |
- |
5/8” |
9-1/4” |
| QR 527 |
65 |
TL07-391 |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 528 |
66 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 530 |
64 |
est. |
UL, 1 hour |
W460, V463, W459, V464 |
5/8” |
9-1/4” |
| QR 545 |
74 |
est. |
- |
- |
1-3/8” |
10-3/4” |
|
More Assembly Types
The information contained in this document is for general information purposes only. Features and specifications are subject to change. The diagrams and stated STC ratings listed are intended to serve as a guide. Construction practices have an influence on final STC ratings. Serious Energy cannot guarantee actual STC ratings. Flanking sound patterns, the integrity of the wall, and floor and ceiling construction are important factors in effective sound control.