PGD-01-10-045

Assembly Components

Assembly Components

Acoustical

STC 55

NRCC TLA-05-050, 9/16/05

Fire

1 hour

U425

4-7/8” Thick, 6.2 lb/ft2

Download Test Report

Description

  • 1-5/8” Type S drywall screws 16” o.c. (1-1/4 in. long, No. 6, Type S screws spaced at 8 in. OC along the perimeter and 12 in. OC in the field. For fire test).

  • One Layer 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.

  • 3-5/8’’ 25 gauge steel studs, 24” o.c.

  • 3.5” glass fiber insulation in stud space.

  • One Layer 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.

  • 1-5/8” Type S drywall screws 16” o.c. (1-1/4 in. long, No. 6, Type S screws spaced at 8 in. OC along the perimeter and 12 in. OC in the field. For fire test).