PGD-01-10-060
Assembly Components

Acoustical
STC 54
RAL TL07-030, 1/25/07
5-3/8” Thick, 6.8 lb/ft2
Description
-
2-1/2 in. Type S drywall screws at 16 in. o.c. (for fire minimum 1-5/8” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field).
-
Face layer: 1/2” QuietRock® 510 applied vertically.
-
1-5/8” Type S drywall screws 16” o.c.
-
Base layer: 5/8” type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
-
3-5/8” 25 gauge steel studs, 24” o.c.
-
3.5” glass fiber insulation in stud space.
-
5/8” type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied horizontally.
-
2-1/2 in. Type S drywall screws at 16 in. o.c. (for fire minimum 1” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field).