Sorry, you need to enable JavaScript to visit this website.

Home

PGD-01-10-060

Assembly Components

Assembly Components

Acoustical

STC 54

RAL TL07-030, 1/25/07

Fire

1 hour

U465

5-3/8” Thick, 6.8 lb/ft2

Description

  • 2-1/2 in. Type S drywall screws at 16 in. o.c. (for fire minimum 1-5/8” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field).

  • Face layer: 1/2” QuietRock® 510 applied vertically.

  • 1-5/8” Type S drywall screws 16” o.c.

  • Base layer: 5/8” type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.

  • 3-5/8” 25 gauge steel studs, 24” o.c.

  • 3.5” glass fiber insulation in stud space.

  • 5/8” type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied horizontally.

  • 2-1/2 in. Type S drywall screws at 16 in. o.c. (for fire minimum 1” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field).