Sorry, you need to enable JavaScript to visit this website.

Home

PGD-01-10-105

Assembly Components

Assembly Components

Acoustical

STC 58

NOAL 17-0509

Fire

1 hour

U465

6” Thick, 7.8 lb/ft2

Download Test Report

Description

  • 1” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field.

  • One Layer 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.

  • 3-5/8” 19 mil (20 ga. EQ) steel studs, 16” o.c.

  • 3-1/2” glass fiber insulation in stud space.

  • Resilient channel applied at right-angle, 24” o.c.

  • Type S-12 screw attaching Resilient Chanel to stud at each intersection.

  • Base layer 5/8” type X (FLAME CURB®, PABCO® Glass Sheathing) gypsum panel applied vertically.

  • 1” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field.

  • Base layer 5/8” type X (FLAME CURB®, PABCO® Glass Sheathing) gypsum panel applied vertically.