Sorry, you need to enable JavaScript to visit this website.

Home

PGD-02-10-010

Assembly Components

Assembly Components

Acoustical

STC 55

RAL TL10-120, 4/14/10

Fire

1 hour

U340

6-3/4” Thick, 7.3 lb/ft2

Download Test Report

Description

  • 1-5/8” Type W drywall screws 12” o.c. (for fire 1-7/8” drywall screws 7” o.c.).

  • One layer 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.

  • 2 x 4 wood studs 16” o.c. staggered 8” o.c. on 2x6 plates.

  • 6-1/4” glass fiber insulation in stud space.

  • One Layer 5/8” Type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.

  • 1-5/8” Type W bugle head drywall screws 12” o.c. (for fire 1-7/8” drywall screws 7” o.c.)