Sorry, you need to enable JavaScript to visit this website.

Home

PGD-02-10-070

Assembly Components

Assembly Components

Acoustical

STC 57

NRCC TLA-04-035, 8/5/04

Fire

1 hour

U305

6” Thick, 9.2 lb/ft2

Download Test Report

Description

  • 2’’  Type S drywall screws 16” o.c (screws spaced at 12 in. OC along the perimeter and 8 in. OC in the field. For fire test).

  • Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.

  • 1-5/8’’ Type S drywall screws 16” o.c (screws spaced at 12 in. OC along the perimeter and 8 in. OC in the field. For fire test).

  • Base layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.

  • 2 x 4 wood studs 24” o.c.

  • 3.5” glass fiber insulation in stud space.

  • Opposite side one layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.

  • 1-5/8’’ Type S drywall screws 16” o.c (screws spaced at 12 in. OC along the perimeter and 8 in. OC in the field. For fire test).