Acoustical

STC 51

OL 11-0319, 3/4/11

Fire

1 hour

U309

4-3/4” Thick, 5.9 lb/ft2

Download Test Report

Description

  • 1-5/8” Type S or W drywall screws 12” o.c. (for fire 1-7/8” drywall screws 7” o.c.).

  • One layer 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.

  • 2 x 4 wood studs 24” o.c.

  • 3.5” glass fiber insulation in stud space.

  • One Layer 5/8” Type X (FLAME CURB®, WATER CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® High Impact, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.

  • 1-5/8” Type S or W drywall screws 12” o.c. (for fire 1-7/8” drywall screws 7” o.c.).