Assembly Components

Assembly Components

Acoustical

STC 57

NOAL 17-0745

Fire

1 hour

U305

5-7/8” Thick, 7.2 lb/ft2

Download Test Report

Description

  • 1-7/8” Type W drywall screws spaced 7” o.c.

  • One Layer 5/8” QuietRock® ES or QuietRock® ES MR Type X gypsum panel applied vertically.

  • 2 x 4 wood studs 16” o.c.

  • 3-1/2” glass fiber insulation in stud space.

  • Resilient channel applied at right-angle, 24” o.c.

  • 1-1/4 Type W pan head screw attaching Resilient Channel to studs.

  • Base layer: type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied horizontally.

  • 1” Type S drywall screws 12” o.c.

  • Face layer:  type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied horizontally.

  • 1-5/8”  Type W drywall screws spaced 12” o.c.